<p>Shunt-Trennverstärker D6S 75000<br />Shunt Isolation Amplifier D6S 75000</p>
Goto Service Web Portal
Webinfo 4 Easy :: 307

Shunt Isolation Amplifier D6S 75000

Isolation and Conversion of Bipolar and Unipolar mV-Signals

With the Isolation Amplifier for Shunt Voltages D6S 75000 DRAGO is extending its offer on high functional and high reliable components of the interface technique.

  • Calibrated signal setting
    Input and output range can be set by using DIP switch - without any further adjustment
  • Zero/Span compensation
    Subsequent readjustment at the zero/span potentiometers on the front panel
  • 3-Port isolation
    Protection against erroneous measurements due to parasitic voltages or ground loops
  • Extremely slim design
    6.0 mm small housing with practical pull-spring clamps
  • Protective Separation acc. to EN 61140
    Protects service personnel and downstream devices against impermissibly high voltage
  • Maximum reliability
    No maintenance costs
  • 5 Years Warranty

The Isolation Amplifier D6S 75000 is used for separation and conversion of bipolar and unipolar mV-signals such as those frequently used for current measuring with shunt-resistors or other applications. Due to the easy selection of the input and output ranges, and the ultra small housing the Isolation Amplifier is suitable for flexible use. High reliability and Protective Separation are further characteristics that make the D6S 75000 unrivaled.

The desired input and output range of D6S 75000 can be easily set by using DIP switch and due to the calibrated range selection no further adjustment is necessary. Also the cut-off frequency can be adapted to the measurement task by using the DIP Switch. A measured range compensation can be performed at the zero/scan potentiometers on the front panel.

Pluggable cross-connectors for the auxiliary power supply ensures fast and economical installation. The slim housing with 6.0 mm wide saves significant space on DIN-rail in the switch cabinet.

The optimized efficiency of the D6S 75000 power pack contributes significantly to reducing the units own heat generation. This is reflected in extremely high MTBF, it means highest reliability and long-term stability. A green LED on the front of the unit has been provided to monitor the power supply.

Technical Data

Input

Input signal
(calibrated range selection)
± 60 mV, ± 100 mV, ± 150 mV, ± 250 mV, ± 300 mV, ± 500 mV
0...60 mV, 0...100 mV, 0...150 mV, 0...250 mV, 0...300 mV, 0...500 mV
Input resistance > 100 kOhm
Overload < 30 V

Output

  Voltage Current
Output signal
(calibrated range selection)
± 10 V, 0...10 V, 2...10 V
± 5 V, 0...5 V, 1...5 V
± 20 mA, 0...20 mA, 4...20 mA
± 10 mA, 0...10 mA, 2...10 mA
Load ≤ 5 mA (2 kOhm at 10 V) ≤ 12 V (600 Ohm at 20 mA)
Offset < 10 mV < 20 µA
Linear transmission range
unipolar: –1 ... +110 %, bipolar: –110 ... +110 %
Ripple < 10 mVrms

General Data

Transmission error < 0.1 % of final value
Temperature coefficient 1)
< 100 ppm/K
Zero/Span compensation ± 10 %
Cut-off frequency (-3 dB) > 10  kHz, switchable to 30 Hz
Test voltage 2.5 kV, 50 Hz
Input against output against power supply
Working voltage 2)
(Basic Insulation)
Up to 600 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61010-1 between all circuits.
Protection against electrical shock 2) Protective separation according to EN 61140 by reinforced insulation in accordance with EN 61010-1 up to 300 V AC/DC for overvoltage category II and pollution degree 2 between all circuits.
Ambient temperature Operation
Transport and storage
–25 °C to +70 °C
–40 °C to +85 °C
Power supply 24 V DC       16.8 V ... 31.2 V, approx. 0.8 W
EMC 3) EN 61326-1
Construction 6.0 mm housing, protection class: IP 20
Weight Approx. 50 g
  1. Average TC based on the final value in specified operating temperature range
  2. As far as relevant the standards and rules mentioned above are considered by development and production of our devices. In addition relevant assembly rules are to be considered by installation of our devices in other equipments. For applications with high working voltages, take measures to prevent accidental contact and make sure that there is sufficient distance or insulation between adjacent situated devices.
  3. Minor deviations possible during interference

Bold: Factory setting for D6S 75000

Block diagram

D6s75000

Dimensions

Gehaeuse6mm zerospan

Terminal assignments
Pull-spring clamps, Wire cross-section max. 2.5 mm², Stripped length 9...10 mm

1 Input + 5 Output +
2 Input - 6 Output -
3 n.c. 7 Power supply +
4 n.c. 8 Power supply -

Product line

Devices Order No.
Shunt Isolation Amplifier, Zero/Span compensation, calibrated range selection D6S 75000    
Shunt Isolation Amplifier, customer specific preselection D6S 75005 - XX - XX

(Factory default setting,
reconfigurable any time by
using DIP-switch)
Input ± 60 mV   50  
0 ... 60 mV   51  
± 100 mV   52  
0 ... 100 mV   53  
± 150 mV   54  
0 ... 150 mV   55  
± 250 mV   56  
0 ... 250 mV   57  
± 300 mV   58  
0 ... 300 mV   59  
± 500 mV   60  
 500 mV   61  
Output ± 10 V     00
0 ... 10 V     01
2 ... 10 V     02
± 5 V     03
0 ... 5 V     04
1 ... 5 V     05
± 20 mA     06
0 ... 20 mA     07
4 ... 20 mA     08
± 10 mA     09
0 ... 10 mA     10
2 ... 10 mA     11
Example:
Shunt Isolation Amplifier,
Input ± 150 mV, Output 4 ... 20 mA

D6S 75005 -

54 -

08
If no information is given by ordering, the devices are delivered with the standard configuration:
Input signal ± 60 mV, Output signal ±10 V.
Subject to change!

Go back

Customer Request at DRAGO