<p>Normsignal-Trennverstärker DN 2000<br />Isolation Amplifier DN 2000</p>
Goto Service Web Portal
Webinfo 4 Easy :: 104

Isolation Amplifier DN 2000

Isolation and Conversion of Standard Signals

With the Isolation Amplifier DN 2000 DRAGO is extending its offer on high-functional and high-reliable components of the interface technique.

  • Calibrated signal setting
    Input and output range can be set by using DIP switch – without any further adjustment
  • Universal Power Supply for 20 ... 253 V AC/DC
    Applicable world-wide for all common supply voltages
  • 3-port isolation
    Protection against erroneous measurements due to parasitic voltages or ground loops
  • Ultra-small-sized housing
    12.5 mm housing with plug-in screw terminal blocks
  • High accuracy
    No falsification of measured signal
  • Protective Separation
    Protects service personnel and downstream devices against impermissibly high voltage
  • Maximum reliability
    No maintenance costs
  • 5 Years Warranty

The Isolation Amplifier DN 2000 is used for isolation and conversion of 0...20 mA, 4...20 mA and 0...10 V standard signals. Due to the calibrated selection of the input and output ranges, the new universal power supply and the ultra-small housing the Isolation Amplifier is suitable for flexible use. The high reliability and the protective separation are further features, which ensure a safe system operation.

The desired input and output range can be easily set by using DIP switch and due to the calibrated range selection no further adjustment is necessary. Also the cut-off frequency can be adapted to the measurement task by using the DIP Switch. Alternatively, all signal combinations are also available in the form of fixed range units.

The slim housing with 12.5 mm width saves space in the switch cabinet and facilitates by the practical plug-in screw terminal blocks the assembly. A simple housing latch has been provided for range setting purposes to make all the operating elements, including those on the DIN-rail, easily accessible.

The new universal power pack for 20...253 V AC/DC means the DN 2000 can be used anywhere in the world, with all mains power supplies. The unit’s high efficiency contributes significantly to reducing the unit’s own heat generation. This is reflected in extremely high reliability and long-term stability. A green LED on the front of the unit has been provided to monitor the power supply.

Technical Data

Input

Input signal 0...20 mA, 4...20 mA, 0...10 V
terminal/switch selectable
Input resistance Current input
Voltage input
22 Ohm
1 MOhm
Input capacitance Approx. 1 nF
Overload Current input
Voltage input
< 200 mA
Voltage limitation via 30 V Z-Diode, max. continuous current 30 mA

Output

Output signal 0...20 mA, 4...20 mA, 0...10 V, switch selectable
Load Current output
Voltage output
≤ 12 V (600 Ohm at 20 mA)
≤ 10 mA (1 kOhm at 10 V)
Linear transmission range –2 ... +110 %
Ripple < 10 mVrms

General Data

Transmission error 0.1 % of final value
Temperature coefficient 2) 50 ppm/K of final value
Cut-off frequency (-3 dB) > 1 kHz,   DN 2000 switchable to < 30 Hz
Test voltage 4 kV, 50 Hz
input against output against power supply
Working voltage 3) (Basic Insulation) Up to 600 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61010-1 between all circuits.
Protection against electrical shock 3) Protective separation according to EN 61140 by reinforced insulation in accordance with EN 61010-1 up to 300 V AC/DC for overvoltage category II and pollution degree 2 between all circuits.
Ambient temperature Operation
Transport and storage
–20 °C to +70 °C
–35 °C to +85 °C
Power supply
20 ... 253 V AC/DC,
AC 48 ... 62 Hz, approx. 2 VA
DC approx. 1.0 W
EMC 4) EMVG, EN 61326 -1
Construction 12.5 mm housing, protection classt: IP 20
Weight Approx. 100 g
  1. Factory setting for DN 2000 AG
  2. Average TC in specified operating temperature range
  3. As far as relevant the standards and rules mentioned above are considered by development and production of our devices. In addition relevant assembly rules are to be considered by installation of our devices in other equipments. For applications with high working voltages, take measures to prevent accidental contact and make sure that there is sufficient distance or insulation between adjacent situated devices.
  4. Minor deviations possible during interference

Bold: Factory setting for DN 2000 AG

Block diagram

Dn2000

Dimensions

GehaeuseHighFunctionality

Terminal assignments
Wire cross-section max. 2,5 mm², Multi-wire connection max. 1 mm² (two wires with same cross-section)

1 Input current + 5 Output +
2 Input current - 6 Output -
3 Input voltage + 7 Power supply ~
4 Input voltage - 8 Power supply ~

Product line

Devices Order No.
Isolation Amplifier, calibrated range selection DN 2000 AG

Input Output
Isolation Amplifier,
fixed setting
0 ... 20 mA 0 ... 20 mA DN 2012 AG
4 ... 20 mA 0 ... 20 mA DN 2032 AG
0 ... 10 V 0 ... 20 mA DN 2052 AG
0 ... 20 mA 4 ... 20 mA DN 2014 AG
4 ... 20 mA 4 ... 20 mA DN 2012 AG
0 ... 10 V 4 ... 20 mA DN 2054 AG
0 ... 20 mA 0 ... 10 V DN 2016 AG
4 ... 20 mA 0 ... 10 V DN 2036 AG
0 ... 10 V 0 ... 10 V DN 2056 AG
Subject to change!